POWER WINDOW DOWN FUNCTION DOES NOT WORK WHEN OPERATING WITH INTELLIGENT KEY PWC-245 < SYMPTOM DIAGNOSIS > [FRONT WINDOW ANTI-PINCH] C D E F G H I J L M A B PWC N O P POWER WINDOW DOWN FUNCTION DOES NOT WORK WHEN OPERAT- Description INFOID:0000000005248335 NOTE: Diagnosis Procedure INFOID:0000000005248336 1. CHECK REMOTE KEYLESS ENTRY FUNCTION Check remote keyless entry function. YES >> GO TO 2. NO >> Go to
2. CHECK POWER WINDOW OPERATION Check power window operation. Does power window up/down with power window main switch? YES >> GO TO 3. NO >> Go to PWC-148, "POWER WINDOW MAIN SWITCH : Diagnosis Procedure" . 3. CHECK “PW DOWN SET” SETTING IN “WORK SUPPORT” Check “PW DOWN SET” setting in “WORK SUPPORT”. DLK-54, "INTELLIGENT KEY : CONSULT-III Function (BCM - INTELLIGENT KEY)" . Is the inspection result normal? YES >> GO TO 4. NO >> Set “PW DOWN SET” setting in “WORK SUPPORT”. 4. CONFIRM THE OPERATION Confirm the operation again. Is the result normal? YES >> Check intermittent incident. Refer to GI-36, "Intermittent Incident" . NO >> GO TO 1. |