INSPECTION AND ADJUSTMENT HAC-5 < BASIC INSPECTION > [AUTOMATIC AIR CONDITIONER] C D E F G H J K L M A B HAC N O P INSPECTION AND ADJUSTMENT WITHOUT ACCS WITHOUT ACCS : Description & Inspection INFOID:0000000005246200 DESCRIPTION The purpose of the operational check is to check that the individual system operates normally. INSPECTION PROCEDURE 1. CHECK MEMORY FUNCTION 1. Start the engine. 2. Turn temperature control dial (driver side) clockwise until 32.0 ° C (90 ° F) is displayed. 3. Press the OFF switch. 4. Turn the ignition switch OFF. 5. Turn the ignition switch ON. 6. Press the AUTO switch. 7. Check that the temperature setting before turning the ignition switch OFF is stored. Is the inspection result normal? YES >> GO TO 2. NO >> Memory function malfunction: HAC-162, "Inspection procedure" 2. CHECK BLOWER MOTOR SPEED 1. Start the engine. 2. Press fan (UP: +) switch. Check that the fan speed changes. Check the operation for all fan speeds. 3. Set the fan speed to max speed. Is the inspection result normal? YES >> GO TO 3. NO >> Blower motor system malfunction: 3. CHECK DISCHARGE AIR 1. Press the MODE switch and the DEF switch. 2. Each position indicator should change shape. 3. Confirm that discharge air comes out according to the air distribution table as follows: NOTE: YES >> GO TO 4. NO >> Mode door system malfunction: . Conditions : Engine running at normal operating temperature JSIIA1208GB |