|
|
System Information Document ____________________________________________________________________________________________________ [Revision: 2.3] ____________________________________________________________________________________________________ Page 27 of 52 Fault Description CARB Ambient 1 Ambient 2 Ambient 3 25 Solenoid valve for TC (short circuit to - or open circuit) P0743 N_MOT AN8 UBATT Pin 32 (Solenoid valve for torque convertor lockup) is either short circuit to 0V or open circuit. Diagnostic operates: Continuously Conditions to be met to run Diagnostic: Torque converter = locked Time between fault present & fault stored: 20 ms Variables used by the diagnostic: Status of torque converter drive, Battery voltage Will limp home mode be selected: Yes Conditions to be met to clear the fault: Ignition to be switched on whilst fault not present, engine cranked. Fault Description CARB Ambient 1 Ambient 2 Ambient 3 26 Solenoid valve 1 (line short circuit to - or open circuit) P0753 N_MOT AN6 UBATT Pin 30 (Solenoid valve 1) is either short circuit to 0V or open circuit. Diagnostic operates: Continuously Conditions to be met to run Diagnostic: Solenoid valve 1 = on Time between fault present & fault stored: 20ms Variables used by the diagnostic: Status of Solenoid valve 1, Battery voltage Will limp home mode be selected: Yes Conditions to be met to clear the fault: Ignition to be switched on whilst fault not present, engine cranked. Fault Description CARB Ambient 1 Ambient 2 Ambient 3 27 Solenoid valve 2 (line short circuit to - or open circuit) P0758 N_MOT AN7 UBATT Pin 33 (Solenoid valve 2) is either short circuit to 0V or open circuit. Diagnostic operates: Continuously Conditions to be met to run Diagnostic: Solenoid valve 2 = on Time between fault present & fault stored: 20 ms Variables used by the diagnostic: Status of Solenoid valve 1, Battery voltage Will limp home mode be selected: Yes Conditions to be met to clear the fault: Ignition to be switched on whilst fault not present, engine cranked. Fault Description CARB Ambient 1 Ambient 2 Ambient 3 28 Pressure regulator (line short circuit to - or open circuit) P0748 N_MOT VGT_$X UBATT Pin 5 (pressure regulator) is either short circuit to 0V or open circuit. Diagnostic operates: Continuously Conditions to be met to run Diagnostic: None Time between fault present & fault stored: 20 ms Variables used by the diagnostic: Status of low side pressure regulator driver Will limp home mode be selected: Yes Conditions to be met to clear the fault: Ignition to be switched on whilst fault not present, engine cranked. Fault Description CARB Ambient 1 Ambient 2 Ambient 3 29 Gear ratio monitoring, 1st gear P0731 N_MOT VGT_$X MMM Ratio of engine speed to output shaft speed whilst 1st gear is engaged is out of range. Diagnostic operates: NAS vehicles only, Continuously Conditions to be met to run Diagnostic: 1 st gear selected, gear shift not in progress Time between fault present & fault stored: 800 ms Variables used by the diagnostic: Engine Speed, Engine Torque, Output shaft speed, Selected gear Will limp home mode be selected: No Conditions to be met to clear the fault: Ignition to be switched on whilst fault not present, engine cranked. |