Specification

Sealant — Blower motor to blower motor housing

WSE-M4G323-A4

Torque specifications

Discription

Nm

lb-ft

Blower

15

11

Heater core and evaporator core housing

15

11

Heater control valve nut

6

4

Heater control valve bolt

22

16

Heating and Ventilation - Blower

Removal and Installation

Removal

1. Remove the air inlet duct. 

For additional information, refer to: 

Air Inlet Duct

 (412-01 Air

Distribution and Filtering, Removal and Installation).

2. 

CAUTION: Make sure that all openings are sealed. Use

new blanking caps.

Disconnect the coolant expansion tank pipe.

Release the clip.

3. Disconnect the recirculation blend door control cable.

Release the clip.

4. Disconnect the blower motor resistor electrical connector.

5. Disconnect the blower motor electrical connector.

5. Disconnect the blower motor electrical connector.

6. Remove the blower.

Remove the 3 nuts.

Installation

1. To install, reverse the removal procedure.

Tighten to 15 Nm (11 lb.ft).

Name
Silicone Sealant

Heating and Ventilation - Blower Motor

Removal and Installation

Materials

Specification
WSE-M4G323-A4 

Removal

• NOTE: LHD shown, RHD similar.

1. Release the coolant expansion tank to radiator pipe.

2. Release the coolant expansion tank.

Remove the bolt.

3. Disconnect the blower motor electrical connector.

4. Remove the blower motor.

 

 

 

 

 

 

 