Symptom: P1747-SOLENOID B SHORTED TO VOLTAGE OR OPEN When Monitored and Set Condition: P1747-SOLENOID B SHORTED TO VOLTAGE OR OPEN When Monitored: Continuously while in 3rd or 4th gear. Set Condition: Solenoid B is turned off and voltage is detected on the Solenoid B Control circuit. POSSIBLE CAUSES INTERMITTENT WIRING AND/OR CONNECTORS OPEN BETWEEN THE 8-WAY CONNECTOR AND TCM CONNECTOR SHORT TO VOLTAGE BETWEEN THE 8-WAY CONNECTOR AND THE TCM CONNECTOR OPEN BETWEEN THE 8-WAY CONNECTOR AND SOLENOID B CONNECTOR OPEN OR HIGH RESISTANCE TRANSMISSION CASE GROUND SHORT TO VOLTAGE BETWEEN THE 8-WAY CONNECTOR AND THE SOLENOID B CONNEC- SOLENOID B - RESISTANCE OUT OF RANGE TCM - SOLENOID B CONTROL CIRCUIT TEST ACTION APPLICABILITY 1 NOTE: Always perform diagnostics with a fully charged battery to avoid t, read the PCM DTC’s. Check and repair all PCM DTC’s before performing transmission diagnostics. t, read the TCM DTC’s. Note: Check 1 trip failures and diagnose them as DTC’s (Hard codes) All Continue 57 TRANSMISSION |