Symptom: LOSS OF IGNITION RUN - START When Monitored and Set Condition: LOSS OF IGNITION RUN - START When Monitored: With the ignition in the Run-Start position the ACM monitors the Fused Ignition Switch Output Run-Start circuit for proper system voltage. Set Condition: If the voltage on the Fused Ignition Switch Output Run-Start circuit drops below approximately 4.5 volts, the code will set. POSSIBLE CAUSES FUSED IGNITION SW OUTPUT RUN-START SHORT TO GROUND IGNITION SWITCH RUN - START CIRCUIT OPEN FUSED IGNITION SWITCH OUTPUT RUN-START CIRCUIT OPEN ACM, FUSED IGNITION OUTPUT RUN-START CIRCUIT OPEN ACM, RUN - START SHORTED TO GROUND ON - OFF SWITCH, RUN - START CIRCUIT SHORTED TO GROUND FUSED IGNITION SWITCH OUTPUT RUN - START CIRCUIT SHORT TO GROUND STORED CODE OR INTERMITTENT CONDITION ACTIVE CODE PRESENT TEST ACTION APPLICABILITY 1 Ensure the battery is fully charged. All ACM - ACTIVE DTC ACM - STORED DTC NOTE: When reconnecting Airbag system components, the ignition must be 2 Turn Ignition off. All Yes → Go To 3 No → Go To 7 33 AIRBAG |