ORC INTERNAL 1 • When Monitored: • Set Condition: Possible Causes ORC Diagnostic Test 1. REPLACE THE ORC NOTE: Ensure that the battery is fully charged. Repair WARNING: If the Occupant Restraint Controller (ORC) is dropped at any time, it must be replaced. Failure to WARNING: To avoid personal injury or death, turn the ignition off, disconnect the battery and wait two min- Replace the ORC in accordance with the Service Information. Perform the *AIRBAG SYSTEM VERIFICATION TEST - VER 1. 8O - 126 RESTRAINTS - ELECTRICAL DIAGNOSTICS KJ |