33–A/C MODE SWITCH STUCK (MTC) (CONTINUED)

5.

CHECK THE (C41) BLOWER SWITCH POSITION SIGNAL CIRCUIT FOR A SHORT TO GROUND

Measure the resistance of the (C41) Blower Switch Position Signal cir-
cuit between ground and the A/C Heater Control C3 harness connec-
tor.

Is the resistance below 10K ohms?

Yes

>> Repair the (C41) Blower Switch Position Signal circuit for

a short to ground.

Perform BODY VERIFICATION TEST - VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).

No

>> Go To 6

6.

CHECK (C41) BLOWER SWITCH POSITION SIGNAL CIRCUIT FOR AN OPEN

Measure the resistance of the (C41) Blower Switch Position Signal cir-
cuit between the A/C Heater Control C2 harness connector and the
A/C Heater Control C3 harness connector.

Is the resistance below 5.0 ohms?

Yes

>> Replace the A/C Heater Control in accordance with the

Service Information.

Perform BODY VERIFICATION TEST - VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).

No

>> Repair the (C41) Blower Switch Position Signal circuit for

an open.

Perform BODY VERIFICATION TEST - VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).

24 - 36

HVAC - ELECTRICAL DIAGNOSTICS

WK

33–A/C MODE SWITCH STUCK (MTC) (CONTINUED)

7.

CHECK THE (C41) BLOWER SWITCH POSITION SIGNAL CIRCUIT FOR A SHORT TO VOLTAGE

Turn the ignition off.

Disconnect the A/C Heater Control C2 harness connector.

Turn the ignition on.

Measure the voltage of the (C41) Blower Switch Position Signal circuit.

Is the voltage above 0.2 volts?

Yes

>> Repair the (C41) Blower Switch Position Signal circuit for

a short to voltage.

Perform BODY VERIFICATION TEST - VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).

No

>> Replace the A/C Heater Control in accordance with the

Service Information.

Perform BODY VERIFICATION TEST - VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).

8.

CHECK FOR NORMAL A/C MODE SWITCH & STATUS INDICATOR FUNCTION

Turn the ignition off.

Reconnect the A/C Heater Control C3 harness connector.

Turn the ignition on.

Turn the Blower control on.

Press the A/C mode switch on and off several times while observing the A/C status indicator.

Does the A/C status indicator turn on and off with respect to the switch position?

Yes

>> Go To 9

No

>> Replace the A/C Heater Control in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).

9.

CHECK A/C HEATER CONTROL OPERATION BY ATTEMPTING TO ENTER DIAGNOSTIC MODE

If illuminated, turn off the A/C status indicator and the EBL status indicator.

Actuate the display DTC function by performing the following:

Turn the blower control on.

Press the A/C mode switch down, turn the blower control to off, wait 5 seconds and then release the A/C mode
switch.

When entry mode is recognized, the A/C status indicator and the EBL status indicator will illuminate for 5 seconds
and then display DTCs, if present. The A/C status indicator displays active DTCs when the EBL status indictor is not
illuminated and stored DTCs when the EBL status indicator is illuminated. However, if no DTCs are present, both
status indicators will turn off and the system will exit diagnostic mode.

Did the A/C Heater Control enter diagnostic mode?

Yes

>> Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL

MODULES - STANDARD PROCEDURE).

No

>> Replace the A/C Heater Control in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).

WK

HVAC - ELECTRICAL DIAGNOSTICS

24 - 37

34–EBL MODE SWITCH STUCK (MTC)

For a complete wiring diagram Refer to Section 8W.

Theory of Operation

The switch input changes when the switch is pushed down. A stored DTC 34 indicates that the EBL mode switch
was stuck in a pushed position for more than 10 minutes, but has since returned to its normal state. An active DTC
34 indicates that the EBL mode switch is stuck in a pushed position. An active DTC 34 will prevent the control from
performing certain diagnostic functions and it will prevent proper EBL mode switch and status indicator function. For
additional information about the A/C Heater Control’s on-board diagnostics, refer to 24 - HEATING & AIR CONDI-
TIONING - DIAGNOSIS AND TESTING.

When Monitored:
With the ignition on.

Set Condition:
If the EBL mode switch stays in a pushed position for more than 10 minutes.

Possible Causes

A/C HEATER CONTROL DAMAGED

OBJECT HOLDING EBL MODE SWITCH IN A PUSHED POSITION

SUBSTANCE CAUSING EBL MODE SWITCH TO GET STUCK IN A PUSHED POSITION

A/C HEATER CONTROL

Diagnostic Test

1.

INSPECT THE A/C HEATER CONTROL FOR DAMAGE

Inspect the A/C Heater Control for damage.

Is the A/C Heater Control damaged?

Yes

>> Replace the A/C Heater Control in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).

No

>> Go To 2

2.

INSPECT FOR OBJECT OR SUBSTANCE CAUSING THE EBL MODE SWITCH TO STAY OR STICK IN A
PUSHED POSITION

Inspect the A/C Heater Control for anything that would cause the EBL mode switch to stay or stick in a pushed
position.

Is anything present that would cause the EBL mode switch to stay or stick in a pushed position?

Yes

>> Repair as necessary.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).

No

>> Go To 3

24 - 38

HVAC - ELECTRICAL DIAGNOSTICS

WK

34–EBL MODE SWITCH STUCK (MTC) (CONTINUED)

3.

CHECK FOR NORMAL EBL MODE SWITCH & STATUS INDICATOR FUNCTION

Turn the ignition on.

Press the EBL mode switch on and off several times while observing the EBL status indicator.

Does the EBL status indicator turn on and off with respect to the switch position?

Yes

>> Go To 4

No

>> Replace the A/C Heater Control in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).

4.

CHECK A/C HEATER CONTROL OPERATION BY ATTEMPTING TO RUN THE ACTUATOR CIRCUIT TEST/
DOOR CALIBRATION FUNCTION

If illuminated, turn off the A/C status indicator and the EBL status indicator.

Actuate the Actuator Circuit Test / Door Calibration Function by performing the following:

Turn the blower control off.

Press and hold the EBL mode switch down and then turn the blower control on. Continue to hold the EBL
mode switch down until the EBL status indicator begins flashing. Then, release the EBL mode switch.

While the test / function is running, the EBL status indicator will flash once per second. If the test / function passes,
the EBL status indicator will stop flashing. If the test / function fails, the A/C and EBL status indicators will flash
alternately.

Did the A/C Heater Control run the test / function?

Yes

>> Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL

MODULES - STANDARD PROCEDURE).

No

>> Replace the A/C Heater Control in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).