Jeep Grand Cherokee WJ. Manual - part 950

 

  Index      Jeep     Jeep Grand Cherokee WJ - service repair manual 2001 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  948  949  950  951   ..

 

 

Jeep Grand Cherokee WJ. Manual - part 950

 

 

7.0

DIAGNOSTIC INFORMATION AND

PROCEDURES

17

Symptom:

P0622-GENERATOR FIELD NOT SWITCHING PROPERLY

When Monitored and Set Condition:

P0622-GENERATOR FIELD NOT SWITCHING PROPERLY

When Monitored:

With the ignition key on and the engine running.

Set Condition:

When the PCM tries to regulate the generator field with no result during

monitoring.

POSSIBLE CAUSES

GENERATOR FIELD WIRING HARNESS INTERMITTENT PROBLEM

GENERATOR FIELD WIRING HARNESS OBSERVABLE PROBLEM

GENERATOR FIELD DRIVER CIRCUIT OPEN

GENERATOR FIELD DRIVER CIRCUIT SHORTED TO GROUND

GENERATOR FIELD RESISTANCE >= 5.0 OHMS

GENERATOR FIELD SOURCE (+) CIRCUIT OPEN

POWERTRAIN CONTROL MODULE

TEST

ACTION

APPLICABILITY

1

Ignition on, engine not running.
With the DRBIII

t, actuate the Generator Field Driver Circuit.

Using a 12-volt test light, backprobe the Generator Field Driver Circuit at the back
of the Generator.
Did the light blink?

All

Yes

Go To

2

No

Go To

3

2

Ignition on, engine not running.
With the DRBIII

t actuate the Generator Field Driver Circuit.

Wiggle Wiring Harness from the Generator to PCM.
With the DRBIII

t, read DTC’s.

Does the Generator Field Driver (-) Circuit code return?

All

Yes

Repair as necessary where wiggling caused problem to appear.
Perform POWERTRAIN VERIFICATION TEST VER - 3.

No

Test Complete.

18

CHARGING

TEST

ACTION

APPLICABILITY

3

Ignition on, engine not running.
Record all DTC’s and freeze frame data, now erase Codes.
Carefully inspect all Connectors for corrosion or spread Terminals before continuing.
With the DRBIII

t actuate the Generator Field Driver Circuit.

Backprobe the Generator Field Source (+) Circuit at back of Generator.
Is the voltage above 10.0 volts?

All

Yes

Go To

4

No

Repair the open Generator Field Source (+) Circuit to Generator.
Perform POWERTRAIN VERIFICATION TEST VER - 3.

4

Turn the ignition off.
Disconnect the PCM harness connector(s).
Disconnect the Generator Field harness connector.
Measure the Generator Field Driver Circuit from PCM Connector to ground.
Is the resistance below 5.0 ohms?

All

Yes

Repair the Generator Field Driver Circuit shorted to ground.
Perform POWERTRAIN VERIFICATION TEST VER - 3.

No

Go To

5

5

Turn the ignition off.
Disconnect the PCM harness connectors.
Disconnect the Generator Field harness connector.
Note: Check Connectors - Clean/repair as necessary.
Measure the Generator Field Driver Circuit from PCM to Generator.
Is the resistance below 5.0 ohms?

All

Yes

Go To

6

No

Repair the open Generator Field Driver Circuit.
Perform POWERTRAIN VERIFICATION TEST VER - 3.

6

Turn the ignition off.
Disconnect the Generator Field harness connector at back of the Generator.
Note: Check connectors - Clean/repair as necessary.
Measure resistance across the Generator Field Terminals at the Generator.
Is the resistance below 5.0 ohms?

All

Yes

Repair the Generator as necessary.
Perform POWERTRAIN VERIFICATION TEST VER - 3.

No

Go To

7

7

If there are no possible causes remaining,
View repair.

All

Repair

Replace and program the Powertrain Control Module in accor-
dance with the Service Information.
Perform POWERTRAIN VERIFICATION TEST VER - 3.

19

CHARGING

P0622-GENERATOR FIELD NOT SWITCHING PROPERLY —

Continued

Symptom:

P0622-GENERATOR FIELD NOT SWITCHING PROPERLY - DIESEL

When Monitored and Set Condition:

P0622-GENERATOR FIELD NOT SWITCHING PROPERLY - DIESEL

When Monitored:

With the engine speed greater than 1500 RPM for at least 25 seconds.

Set Condition:

When the PCM tries to regulate the generator output with no result

during monitoring.

POSSIBLE CAUSES

INTERMITTENT CONDITION

CHECK FOR OTHER CHARGING SYSTEM DTCS

GENERATOR FIELD CIRCUIT OPEN

GENERATOR SOURCE CIRCUIT OPEN

POWERTRAIN CONTROL MODULE (INTERNAL DRIVER FAULT)

GENERATOR (FIELD OPEN)

POWERTRAIN CONTROL MODULE (GENERATOR SOURCE OPEN)

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRB, read PCM DTCs.
Are there any other Charging System related DTCs?

All

Yes

Refer to the symptom list for the related symptom(s).
Perform CHARGING VERIFICATION - VER-3.

No

Go To

2

2

NOTE: The battery must be fully charged and the generator belt must be in
good condition and tensioned properly before continuing.
Turn the ignition on.
With the DRB, erase PCM DTCs.
Turn the ignition off for 10 seconds, then start the engine.
With the DRB, read PCM DTCs.
Did this DTC reset?

All

Yes

Go To

3

No

Go To

7

3

Turn the ignition off, then on.
Measure the voltage of the Generator Field Driver circuit in PCM harness connector
C2 by back probing.
Is the voltage above 10.0 volts?

All

Yes

Replace and program the Powertrain Control Module in accor-
dance with the Service Information.
Perform CHARGING VERIFICATION - VER-3.

No

Go To

4

20

CHARGING

 

 

 

 

 

 

 

Content   ..  948  949  950  951   ..