Jeep Grand Cherokee WJ. Manual - part 569

 

  Index      Jeep     Jeep Grand Cherokee WJ - service repair manual 2001 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  567  568  569  570   ..

 

 

Jeep Grand Cherokee WJ. Manual - part 569

 

 

HVAC SYSTEM POINTER

Pointer Number

DESCRIPTION

Value Displayed

01

A/C Enable

0 or 1

0 = disabled 1 =
enabled

02

Final fan PWM duty cycle

0 to 255

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

03

Left NPRG *

0 to 255

* NPRG equals a calculated number based on outside and in-vehicle conditions. This value is used by the AZC to

position the Mode motor, Air Inlet motor, and control blower motor speed.

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

04

Right NPRG

0 to 255

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

05

Avg NPRG

0 TO 255

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

06

Primary control side

0 or 1

0 = left 1 = right

07

EE Check sum (calculated)

0 to 255

08

Target intensity (in % ON time)

0 to 255

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

09

Not Used

0 to 0

10

Not Used

0 to 0

11

Right NINC *

0 to 255

* NINC equals a calculated number based on the IR sensor and IR thermistor values used to calculate the NPRG.

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

12

Left NINC

0 to 255

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

13

Right NMIX *

0 to 255

* NMIX equals a calculated number based on outside and in-vehicle conditions used by the AZC to position the

Temperature motors.

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

24 - 18

HEATING AND AIR CONDITIONING

WJ

DIAGNOSIS AND TESTING (Continued)

HVAC SYSTEM POINTER

14

Left NMIX

0 to 255

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CW = decrease

15

Not Used

0 to 0

16

Not Used

0 to 0

17

Reserved

18

Reserved

19

Reserved

MODE VALUE POINTER

Pointer Number

DESCRIPTION

Value Displayed

20

mode range in delta counts

0 to 9999

21

Current mode position (in counts)

0 to 9999

22

mode target position in ratio

0 to 255

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

23

mode target position in counts

0 to 9999

24

Not Used

0 to 0

25

number of valve moves since last index

0 to 9999

26

Not Used

0 to 0

27

Not Used

0 to 0

28

Not Used

0 to 0

29

mode motor state

0 to 5

0 = in position, 1 = moving toward panel, 2 = moving toward
defrost, 3 = searching range, 4 = stalled moving toward panel, 5 =
stalled moving toward defrost

LEFT SIDE TEMPERATURE POINTER

Pointer Number

DESCRIPTION

Value Displayed

30

Left side temp range in delta counts

0 to 9999

31

Current left side temp position (in counts)

0 to 9999

32

Left side temp target position (in ratio)

0 to 255

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

33

Left side temp target in counts

0 to 9999

34

Not used

0 to 0

35

number of valve moves since last index

0 to 9999

36

Not used

0 to 0

37

Not used

0 to 0

38

Not used

0 to 0

39

Left side temp motor state

0 to 5

WJ

HEATING AND AIR CONDITIONING

24 - 19

DIAGNOSIS AND TESTING (Continued)

LEFT SIDE TEMPERATURE POINTER

0 = in position, 1 = moving toward panel, 2 = moving toward
defrost, 3 = searching range, 4 = stalled moving toward panel, 5 =
stalled moving toward defrost

RIGHT SIDE TEMPERATURE POINTER

Pointer Number

DESCRIPTION

Value Displayed

40

Right side temp range in delta counts

0 to 9999

41

Current right side temp position (in counts)

0 to 9999

42

Right side temp target position (in ratio)

0 to 255

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

43

Right side temp target in counts

0 to 9999

44

Not used

0 to 0

45

number of valve moves since last index

0 to 9999

46

Not used

0 to 0

47

Not used

0 to 0

48

Not used

0 to 0

49

Right side temp motor state

0 to 5

0 = in position, 1 = moving toward panel, 2 = moving toward
defrost, 3 = searching range, 4 = stalled moving toward panel, 5 =
stalled moving toward defrost

AIR INLET POINTER

Pointer Number

DESCRIPTION

Value Displayed

50

Air inlet range (in counts)

0 to 9999

51

Current air inlet position (in counts)

0 to 9999

52

Air inlet target position (in ratio)

0 to 255

While the value of this pointer is being displayed, turning the right
set temperature control either direction will manually control the
value. CW = increase; CCW = decrease

53

Air inlet target in counts

0 to 9999

54

Not used

0 to 0

55

number of motor moves since last index

0 to 9999

56

Not used

0 to 0

57

Not used

0 to 0

58

Not used

0 to 0

59

Air inlet motor state

0 to 5

0 = in position, 1 = moving toward panel, 2 = moving toward
defrost, 3 = searching range, 4 = stalled moving toward panel, 5 =
stalled moving toward defrost

60

Reserved

61

Actual Outside Air Temp (in degrees F)

-40 to 215

62

Not used

0 to 0

63

Engine Intake Air Temperature (in degrees F)

-40 to 215

24 - 20

HEATING AND AIR CONDITIONING

WJ

DIAGNOSIS AND TESTING (Continued)

AIR INLET POINTER

64

Vehicle speed in MPH

0 to 255

65

Engine RPM/100

-0 to 82

66

Engine Coolant Temp - 40 (in degrees F)

-40 to 215

67

Country Code

0 to 255

68

Not used

0 to 0

69

Not used

0 to 0

IR SENSOR POINTER

Pointer Number

DESCRIPTION

Value Displayed

70

Thermistor temp (in degrees)

-40 to 215

71

Left side sensor A/D (filtered)

0 to 255

72

Right side sensor A/D (filtered)

0 to 255

73

Left side temp (in degrees F)

-40 to 140

74

Right side temp (in degrees F)

-40 to 140

75

Not used

0 to 0

76

Not used

0 to 0

77

Not used

0 to 0

78

Not used

0 to 0

79

Not used

0 to 0

IDENTIFICATION POINTER

Pointer Number

DESCRIPTION

Value Displayed

80

ROM bit pattern number (digits 1,2,3 & 4)

0 to 9999

81

ROM bit pattern number (digits 5,6,7 & 8)

0 to 9999

82

CAL bit pattern number (digits 1,2,3 & 4)

0 to 9999

83

CAL bit pattern number (digits 5,6,7 & 8)

0 to 9999

84

Not used

0 to 0

85

Not used

0 to 0

86

Not used

0 to 0

87

Not used

0 to 0

88

Not used

0 to 0

89

Not used

0 to 0

WJ

HEATING AND AIR CONDITIONING

24 - 21

DIAGNOSIS AND TESTING (Continued)

 

 

 

 

 

 

 

Content   ..  567  568  569  570   ..