Jeep Grand Cherokee WJ. Manual - part 1003

 

  Index      Jeep     Jeep Grand Cherokee WJ - service repair manual 2001 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  1001  1002  1003  1004   ..

 

 

Jeep Grand Cherokee WJ. Manual - part 1003

 

 

TEST

ACTION

APPLICABILITY

5

Turn the ignition off.
Disconnect the PCM harness connector(s).
Remove the Radiator Fan Relay for the PDC.
Measure the resistance of the Radiator Fan Relay Control circuit form PDC to PCM
harness connector.
Is the resistance below 5.0 ohms?

All

Yes

Go To

6

No

Repair the open Radiator Fan Relay Control Circuit.
Perform POWERTRAIN VERIFICATION TEST VER - 2.

6

Turn the ignition off.
Remove the Radiator Fan Relay from the PDC.
Disconnect the PCM harness connector(s).
Measure the resistance between ground and the Radiator Fan Relay Control circuit.
Is the resistance above 100 kohms?

All

Yes

Go To

7

No

Repair the Radiator Fan Relay Control Circuit for a short to
ground.
Perform POWERTRAIN VERIFICATION TEST VER - 2.

7

Turn the ignition off.
Disconnect the PCM harness connector(s).
Connect a jumper wire to the Radiator Fan Relay Control circuit in the PCM harness
connector.
Momentarily connect the other end of the jumper wire to ground.
Did the Radiator Fan actuate?

All

Yes

Go To

8

No

Replace the Radiator Fan Relay.
Perform POWERTRAIN VERIFICATION TEST VER - 2.

8

If there are no possible causes remaining, view repair.

All

Repair

Replace and program the Powertrain Control Module in accor-
dance with the Service Information.
Perform POWERTRAIN VERIFICATION TEST VER - 2.

229

DRIVEABILITY - GAS

P1491-RAD FAN CONTROL RELAY CIRCUIT —

Continued

Symptom:

P1494-LEAK DETECTION PUMP SW OR MECHANICAL FAULT

When Monitored and Set Condition:

P1494-LEAK DETECTION PUMP SW OR MECHANICAL FAULT

When Monitored:

Immediately after a cold start, with battery/ambient temperature

between 40 deg. F and 90 deg. F and coolant temperature within 10 deg. F of battery/
ambient.

Set Condition:

The state of the switch does not change when the solenoid is energized.

POSSIBLE CAUSES

WIRING HARNESS INTERMITTENT

LDP SWITCH SENSE CIRCUIT SHORTED TO GROUND

LDP VACUUM SUPPLY

LEAK DETECTION PUMP

LDP SWITCH SENSE CIRCUIT OPEN

POWERTRAIN CONTROL MODULE

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRBIII

t, read DTC’s.

Is the DTC Good Trip Counter displayed and equal to zero for P-1494?

All

Yes

Go To

2

No

Go To

7

2

Turn the ignition off.
Disconnect the vacuum supply hose at the Leak Detection Pump.
Connect a vacuum gauge to the disconnected vacuum supply hose at the Leak
Detection Pump.
Start the engine and read the vacuum gauge.
Does the vacuum gauge read at least 13 in/Hg?

All

Yes

Go To

3

No

Repair leak or obstruction in vacuum hose as necessary.
Perform POWERTRAIN VERIFICATION TEST VER - 6.

230

DRIVEABILITY - GAS

TEST

ACTION

APPLICABILITY

3

Turn the ignition off.
Disconnect the Leak Detection Pump harness connector.
Disconnect the PCM harness connector(s).
Note: Check connectors - Clean/repair as necessary.
Measure the resistance of the LDP Switch Sense Circuit from the PCM harness
connector to LDP harness connector.
Is the resistance below 5.0 ohms?

All

Yes

Go To

4

No

Repair the open Leak Detection Pump Switch Sense Circuit.
Perform POWERTRAIN VERIFICATION TEST VER - 6.

4

Turn the ignition off.
Disconnect the Leak Detection Pump electrical harness connector.
Turn the ignition on.
With the DRBIII

t in Inputs/Outputs, read the 9Leak Detect Pump Sw9 state.

While observing the

9Leak Detect Pump Sw9 state, connect a jumper wire between a

good 12 volt source (B+) and the LDP Switch Sense circuit.
Did the

9Leak Detect Pump Sw9 state change when the jumper was connected?

All

Yes

Replace the Leak Detection Pump.
Perform POWERTRAIN VERIFICATION TEST VER - 6.

No

Go To

5

5

Turn the ignition off.
Disconnect the Leak Detection Pump electrical harness connector.
Disconnect the PCM harness connector(s).
Measure the resistance between the LDP Switch Sense circuit and ground.
Is the resistance below 5.0 Ohms?

All

Yes

Repair the LDP Switch Sense Circuit for a short to ground.
Perform POWERTRAIN VERIFICATION TEST VER - 6.

No

Go To

6

6

If there are no possible causes remaining, view repair.

All

Repair

Replace and program the Powertrain Control Module in accor-
dance with the Service Information.
Perform POWERTRAIN VERIFICATION TEST VER - 6.

7

At this time, the conditions required to set the DTC are not present.
Note: Use the Freeze Frame Data to help you duplicate the conditions that
set the DTC. Pay particular attention to the DTC set conditions, such as,
VSS, MAP, ECT, and Load.
Note: Visually inspect the related wiring harness. Look for any chafed,
pierced, pinched, or partially broken wires.
Note: Visually inspect the related wire harness connectors. Look for broken,
bent, pushed out, or corroded terminals.
Note: Refer to any Technical Service Bulletins (TSB’s) that may apply.
Perform a wiggle test of the LDP wiring while the circuit is actuated with the
DRBIII

t. Listen for the LDP to quit actuating. Also watch for the Good Trip Counter

to change to 0.
Were any problems found?

All

Yes

Repair wiring harness/connectors as necessary.
Perform POWERTRAIN VERIFICATION TEST VER - 6.

No

Test Complete.

231

DRIVEABILITY - GAS

P1494-LEAK DETECTION PUMP SW OR MECHANICAL FAULT —

Continued

Symptom:

P1495-LEAK DETECTION PUMP SOLENOID CIRCUIT

When Monitored and Set Condition:

P1495-LEAK DETECTION PUMP SOLENOID CIRCUIT

When Monitored:

Ignition on and battery voltage greater than 10.4 volts.

Set Condition:

The state of the solenoid circuit does not match the PCM’s desired state.

POSSIBLE CAUSES

LDP SOLENOID CIRCUIT WIRING HARNESS OBSERVABLE

LDP SOLENOID CKT WIRING HARNESS INTERMITTENT

GENERATOR SOURCE CIRCUIT OPEN

LDP SOLENOID CONTROL CIRCUIT SHORTED TO GROUND

LEAK DETECTION PUMP

LEAK DETECTION PUMP SOLENOID CONTROL CIRCUIT OPEN

POWERTRAIN CONTROL MODULE

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRBIII

t, read DTC’s.

Is the DTC Good Trip Counter displayed and equal to zero for P-1495?

All

Yes

Go To

2

No

Go To

8

2

Turn the ignition off.
Disconnect the Leak Detection Pump electrical harness connector.
Turn the ignition on.
With the DRBIII

t, actuate the Leak Detection Pump.

Using a 12 volt test light connected to ground (B-), check the Generator Source
Circuit at the LDP connector.
Does the test light illuminate brightly?

All

Yes

Go To

3

No

Repair the open Generator Source Circuit.
Perform POWERTRAIN VERIFICATION TEST VER - 6.