DLK-182 < SYMPTOM DIAGNOSIS > P RANGE INTERLOCK DOOR LOCK/UNLOCK FUNCTION DOES NOT OPER- ATE P RANGE INTERLOCK DOOR LOCK/UNLOCK FUNCTION DOES NOT OP- Diagnosis Procedure INFOID:0000000006226020 1. CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT” mode. 3. Check “AUTOMATIC LOCK/UNLOCK SELECT” setting in “WORK SUPPORT”. DLK-39, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK)" . Is the inspection result normal? YES >> GO TO 2. NO >> Set “Unlock Only”, “Lock Only” or “Lock/Unlock” in “AUTOMATIC LOCK/UNLOCK SELECT”. 2. CHECK “AUTOMATIC DOOR LOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC DOOR LOCK SELECT” in “WORK SUPPORT” mode. 3. Check “AUTOMATIC DOOR LOCK SELECT” setting in “WORK SUPPORT”. DLK-39, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK)" . Is the inspection result normal? YES >> GO TO 3. NO >> Set “P RANGE” in “AUTOMATIC DOOR LOCK SELECT”. 3. CHECK “AUTOMATIC DOOR UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT” mode. 3. Check “AUTOMATIC DOOR UNLOCK SELECT” setting in “WORK SUPPORT”. DLK-39, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK)" . Is the inspection result normal? YES >> GO TO 4. NO >> Set “MODE 2” or “MODE 4” in “AUTOMATIC DOOR UNLOCK SELECT”. 4. REPLACE BCM • Replace BCM. Refer to BCS-81, "Removal and Installation" . • Confirm the operation after replacement. Is the result normal? YES >> INSPECTION END NO >> Check intermittent incident. Refer to GI-40, "Intermittent Incident" . |