DLK-126 < DTC/CIRCUIT DIAGNOSIS > DOOR LOCK ACTUATOR 3. Check continuity between BCM harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness. 3. CHECK BCM OUTPUT SIGNAL 1. Connect BCM connector. 2. Check voltage between BCM harness connector and ground. Is the inspection result normal? YES >> Check for internal short of each door lock actuator and fuel lid lock actuator. NO >> Replace BCM. Refer to BCS-81, "Removal and Installation" REAR RH REAR RH : Component Function Check INFOID:0000000006225937 1. CHECK FUNCTION 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “DOOR LOCK” in “ACTIVE TEST” mode. 3. Touch “ALL LOCK” or “ALL UNLK” to check that it works normally. Is the inspection result normal? YES >> Door lock actuator is OK. NO >> Refer to DLK-126, "REAR RH : Diagnosis Procedure" REAR RH : Diagnosis Procedure INFOID:0000000006225938 1. CHECK DOOR LOCK ACTUATOR INPUT SIGNAL 1. Turn ignition switch OFF. 2. Disconnect rear door lock assembly RH connector. 3. Check voltage between rear door lock assembly RH harness connector and ground. Is the inspection result normal? BCM Rear door lock assembly LH Continuity Connector Terminal Connector Terminal M69 55 D65 2 Existed M70 65 1 BCM Ground Continuity Connector Terminal M69 55 Not existed M70 65 (+) (–) Condition Voltage (Approx.) BCM Connector Terminal M69 55 Ground Door lock and unlock switch Unlock 12 V M70 65 Lock (+) (–) Condition Voltage (Approx.) Rear door lock assembly RH Connector Terminal D45 1 Ground Door lock and unlock switch Unlock 12 V 2 Lock |