DTC P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1137 [VK45DE] C D E F G H I J K L M A EC DTC Confirmation Procedure NBS005I1 NOTE: WITH CONSULT-II 1. Turn ignition switch OFF and wait at least 10 seconds. 2. Turn ignition switch ON and select “DATA MONITOR” mode with 3. Start engine and wait at least 40 seconds. NOTE: . WITH GST Follow the procedure “WITH CONSULT-II” above. Diagnostic Procedure NBS005I2 1. CHECK GROUND CONNECTIONS 1. Turn ignition switch OFF. 2. Loosen and retighten ground screws on the body. OK or NG OK >> GO TO 2. NG >> Repair or replace ground connections. SEF194Y 1. Body ground M70 2. Body ground M16 PBIB2782E |