PRECAUTIONS

ATC-15

C

D

E

F

G

H

I

K

L

M

A

B

ATC

Precautions for Leak Detection Dye

NJS000FV

The A/C system contains a fluorescent leak detection dye used for locating refrigerant leaks. An ultraviolet
(UV) lamp is required to illuminate the dye when inspecting for leaks.

Always wear fluorescence enhancing UV safety goggles to protect your eyes and enhance the visibility of
the fluorescent dye.

The fluorescent dye leak detector is not a replacement for an electrical leak detector (SST: J-41995). The
fluorescent dye leak detector should be used in conjunction with an electrical leak detector (SST: J-41995)
to pin-point refrigerant leaks.

For the purpose of safety and customer’s satisfaction, read and follow all manufacture’s operating instruc-
tions and precautions prior to performing the work.

A compressor shaft seal should not necessarily be repaired because of dye seepage. The compressor
shaft seal should only be repaired after confirming the leak with an electrical leak detector (SST: J-41995).

Always remove any remaining dye from the leak area after repairs are completed to avoid a misdiagnosis
during a future service.

Never allow dye to come into contact with painted body panels or interior components. If dye is spilled,
clean immediately with the approved dye cleaner. Fluorescent dye left on a surface for an extended period
of time cannot be removed.

Never spray the fluorescent dye cleaning agent on hot surfaces (engine exhaust manifold, etc.).

Never use more than one refrigerant dye bottle (1/4 ounce /7.4 cc) per A/C system.

Leak detection dyes for HFC-134a (R-134a) and CFC-12 (R-12) A/C systems are different. Never use
HFC-134a (R-134a) leak detection dye in CFC-12 (R-12) A/C system, or CFC-12 (R-12) leak detection
dye in HFC-134a (R-134a) A/C system, or A/C system damage may result.

The fluorescent properties of the dye will remain for three years or a little over unless a compressor mal-
function occurs.

IDENTIFICATION

NOTE:
Vehicles with factory installed fluorescent dye have a green label.
Vehicles without factory installed fluorescent dye have a blue label.

IDENTIFICATION LABEL FOR VEHICLE

Vehicles with factory installed fluorescent dye have the identification label on the front side of hood.

ATC-16

PREPARATION

PREPARATION

PFP:00002

Special Service Tools

NJS000FW

The actual shapes of Kent-Moore tools may differ from those of special service tools illustrated here.

Tool number
(Kent-Moore No.)
Tool name

Description

9253089908
(for high-pressure pipe 1)
(-)
9253089912
(for high-pressure flexible hose)
(-)
9253089916
(for low-pressure pipe 1 and 
low-pressure flexible hose)
(-)
Disconnector tool set
(J-45815)

Disconnect one-touch joint connection

SJIA1274E

PREPARATION

ATC-17

C

D

E

F

G

H

I

K

L

M

A

B

ATC

HFC-134a (R-134a) Service Tools and Equipment

NJS000FX

Never mix HFC-134a (R-134a) refrigerant and/or its specified lubricant with CFC-12 (R-12) refrigerant and/or
its lubricant.
Separate and non-interchangeable service equipment must be used for handling each type of refrigerant/lubri-
cant.
Refrigerant container fittings, service hose fittings and service equipment fittings (equipment which handles
refrigerant and/or lubricant) are different between CFC-12 (R-12) and HFC-134a (R-134a). This is to avoid
mixed use of the refrigerants/lubricant.
Never use adapters that convert one size fitting to another: refrigerant/lubricant contamination occurs and
compressor malfunction may result.

Tool number
(Kent-Moore No.)
Tool name

Description

HFC-134a (R-134a) refrigerant

Container color: Light blue
Container marking: HFC-134a (R-
134a)
Fitting size: Thread size

Large container 1/2

 -16 ACME

Nissan A/C System Oil Type S 
(DH-PS)

Type: Polyalkylene glycol oil (PAG), 
type S (DH-PS)
Application: 
HFC-134a (R-134a) swash plate 
compressors (Nissan only)

Capacity: 40 m

 (1.4 US fl oz., 1.4 

Imp fl oz.) 

(ACR2005-NI)
ACR5 A/C Service Center

Function: Refrigerant recovery, 
recycling and recharging

(J-41995)
Electrical A/C leak detector

Power supply:
DC 12 V (Battery terminal)

S-NT196

S-NT197

WJIA0293E

AHA281A

ATC-18

PREPARATION

(J-43926)
Refrigerant dye leak detection kit
Kit includes:
(J-42220)
UV lamp and UV safety goggles
(J-41459)
HFC-134a (R-134a) dye injector
Use with J-41447, 1/4 ounce 
bottle
(J-41447)
HFC-134a (R-134a) fluorescent 
leak detection dye
(Box of 24, 1/4 ounce bottles)
(J-43872) 
Refrigerant dye cleaner

Power supply:
DC 12 V (Battery terminal)

(J-42220)
 UV lamp and UV safety goggles

Power supply:
DC 12 V (Battery terminal)
For checking refrigerant leak when 
fluorescent dye is installed in A/C 
system
Includes:
UV lamp and UV safety goggles

(J-41447)
HFC-134a (R-134a) fluorescent 
leak detection dye
(Box of 24, 1/4 ounce bottles)

Application:
For HFC-134a (R-134a) PAG oil
Container:
1/4 ounce (7.4 cc) bottle
(Includes self-adhesive dye 
identification labels for affixing to 
vehicle after charging system with 
dye.)

(J-41459)
HFC-134a (R-134a) dye injector
Use with J-41447, 1/4 ounce 
bottle

For injecting 1/4 ounce of fluorescent 
leak detection dye into A/C system

(J-43872)
Refrigerant dye cleaner

For cleaning dye spills

(J-39183)
Manifold gauge set (with hoses 
and couplers)

Identification:

The gauge face indicates HFC-134a 
(R-134a).

Fitting size: Thread size

1/2

 -16 ACME

Tool number
(Kent-Moore No.)
Tool name

Description

ZHA200H

SHA438F

SHA439F

SHA440F

SHA441F

RJIA0196E

 

 

 

 

 

 

 