Infiniti G35 (V35) Sedan. Manual - part 797

 

  Index      Infiniti     Infiniti G35 (V35) Sedan - service repair manual 2007 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  795  796  797  798   ..

 

 

Infiniti G35 (V35) Sedan. Manual - part 797

 

 

INL-16

< FUNCTION DIAGNOSIS >

DIAGNOSIS SYSTEM (BCM)

ACTIVE TEST

*: Each lamp switch is in ON position.

Monitor item

[Unit]

Description

REQ SW-DR
[ON/OFF]

The switch status input from request switch (driver side)

REQ SW-AS
[ON/OFF]

The switch status input from front request switch (passenger side)

PUSH SW
[ON/OFF]

The switch status input from push-button ignition switch

ACC RLY-F/B
[ON/OFF]

ACC relay feedback signal status input from ACC relay

KEY SW-SLOT
[ON/OFF]

Key switch status input from key slot

DOOR SW-DR
[ON/OFF]

The switch status input from front door switch (driver side)

DOOR SW-AS
[ON/OFF]

The switch status input from front door switch (passenger side)

DOOR SW-RR
[ON/OFF]

The switch status input from rear door switch RH

DOOR SW- RL
[ON/OFF]

The switch status input from rear door switch LH

DOOR SW-BK
[ON/OFF]

NOTE:
The item is indicated, but not monitored.

CDL LOCK SW
[ON/OFF]

Lock switch status received from central door lock switch by power window switch se-
rial link

CDL UNLOCK SW
[ON/OFF]

Unlock switch status received from central door lock switch by power window switch 
serial link

KEY CYL LK-SW
[ON/OFF]

Lock switch status received from key cylinder switch by power window switch serial 
link

KEY CYL UN-SW
[ON/OFF]

Unlock switch status received from key cylinder switch by power window switch serial 
link

TRNK/HAT MNTR
[ON/OFF]

The switch status input from trunk room lamp switch

RKE-LOCK
[ON/OFF]

Lock signal status received from remote keyless entry receiver

RKE-UNLOCK
[ON/OFF]

Unlock signal status received from remote keyless entry receiver

Test item

Operation

Description

BATTERY SAVER

OFF

Cuts the interior room lamp power supply to turn interior room lamp OFF.

ON

Outputs the interior room lamp power supply to turn interior room lamp ON.*

POWER SUPPLY AND GROUND CIRCUIT

INL-17

< COMPONENT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

M

A

B

INL

N

O

P

COMPONENT DIAGNOSIS

POWER SUPPLY AND GROUND CIRCUIT

BCM

BCM : Diagnosis Procedure

INFOID:0000000000962580

1.

CHECK FUSE AND FUSIBLE LINK

Check that the following fuse and fusible link are not blown.

Is the fuse fusing?

YES

>> Replace the blown fuse or fusible link after repairing the affected circuit if a fuse or fusible link is

blown.

NO

>> GO TO 2.

2.

CHECK POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect BCM connectors.

3.

Check voltage between BCM harness connector and ground.

Is the measurement value normal?

YES

>> GO TO 3.

NO

>> Repair harness or connector.

3.

CHECK GROUND CIRCUIT

Check continuity between BCM harness connector and ground.

Does continuity exist?

YES

>> INSPECTION END

NO

>> Repair harness or connector.

BCM : Special Repair Requirement

INFOID:0000000000962581

1.

REQUIRED WORK WHEN REPLACING BCM

Initialize IVIS by CONSULT-III. For the details of initialization refer to CONSULT-III operation manual NATS-
IVIS/NVIS.

>> Work end.

Terminal No.

Signal name

Fuse and fusible link No.

1

Battery power supply

K

11

10

Terminals

Voltage

(Approx.)

(+)

(

)

BCM

Ground

Connector

Terminal

M118

1

Battery voltage

M119

11

BCM

Ground

Continuity

Connector

Terminal

M119

13

Existed

INL-18

< COMPONENT DIAGNOSIS >

INTERIOR ROOM LAMP POWER SUPPLY CIRCUIT

INTERIOR ROOM LAMP POWER SUPPLY CIRCUIT

Description

INFOID:0000000000962582

Provides the interior room lamp power supply. Also cuts the power supply when the interior room lamp battery
saver activating.

Component Function Check

INFOID:0000000000962583

1.

CHECK INTERIOR ROOM LAMP POWER SUPPLY FUNCTION

CONSULT-III ACTIVE TEST

1.

Turn ignition switch ON.

2.

Turn each interior room lamp ON.

-

Map lamp

-

Personal lamp

-

Step lamp

-

Vanity mirror lamp

-

Trunk room lamp

3.

Select "BATTERY SAVER" of BCM (BATTERY SAVER) active test item.

4.

 With operating the test items, check that each interior room lamp turns ON/OFF.

Does the interior room lamp turn ON/OFF?

YES

>> Interior room lamp power supply circuit is normal.

NO

>> Refer to 

INL-18, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000000962584

1.

CHECK INTERIOR ROOM LAMP POWER SUPPLY OUTPUT

CONSULT-III ACTIVE TEST

1.

Turn ignition switch ON.

2.

Select “BATTERY SAVER” of BCM (BATTERY SAVER) active test item.

3.

With operating the test item, check voltage between BCM harness connector and ground.

Is the measurement value normal?

YES

>> GO TO 2.

NO

>> Replace BCM.

2.

CHECK INTERIOR ROOM LAMP POWER SUPPLY OPEN CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect the following connectors.

-

Map lamp

-

Personal lamp

-

Vanity mirror lamp (LH)

-

Vanity mirror lamp (RH)

-

Trunk room lamp

-

Step lamp (driver side)

-

Step lamp (passenger side)

OFF

: Interior room lamp OFF

ON

: Interior room lamp ON

Terminals

Test item

Voltage (Ap-

prox.)

(+)

(-)

BCM

Ground

BATTERY 

SAVER

Connector

Terminal

M119

4

OFF

0 V

ON

Battery volt-

age

INTERIOR ROOM LAMP POWER SUPPLY CIRCUIT

INL-19

< COMPONENT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

M

A

B

INL

N

O

P

3.

Check continuity between BCM harness connector and each interior room lamp harness connector.

Does continuity exist?

YES

>> GO TO 3.

NO

>> Repair the harnesses or connectors.

3.

CHECK INTERIOR ROOM LAMP POWER SUPPLY SHORT CIRCUIT

Check continuity between BCM harness connector and ground.

Does continuity exist?

YES

>> Repair the harnesses or connectors.

NO

>> Check that each interior room lamp has no internal short circuit.

BCM

Each interior room lamp

Continu-

ity

Connec-

tor

Terminal

Connector

Terminal

M119

4

Map lamp

R15

1

Existed

Personal lamp

R14

1

Vanity mirror lamp 
(LH)

R12

2

Vanity mirror lamp 
(RH)

R13

2

Trunk room lamp

B47

1

Step lamp (driver 
side)

D12

1

Step lamp (pas-
senger side)

D42

1

BCM

Ground

Continuity

Connector

Terminal

M119

4

Not existed

 

 

 

 

 

 

 

Content   ..  795  796  797  798   ..