Infiniti G35 (V35) Sedan. Manual - part 534

 

  Index      Infiniti     Infiniti G35 (V35) Sedan - service repair manual 2007 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  532  533  534  535   ..

 

 

Infiniti G35 (V35) Sedan. Manual - part 534

 

 

EC-282

< COMPONENT DIAGNOSIS >

[VQ35HR]

P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE

5.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR

1.

Disconnect EVAP control system pressure sensor harness connector.

2.

Check connectors for water.

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> Replace EVAP control system pressure sensor.

6.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

Refer to 

EC-298, "Component Inspection"

.

Is the inspection result normal?

YES-1 >> With CONSULT-III: GO TO 7.
YES-2 >> Without CONSULT-III: GO TO 8.
NO

>> Replace EVAP control system pressure sensor.

7.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE

 With CONSULT-III

1.

Turn ignition switch OFF.

2.

Reconnect harness connectors disconnected.

3.

Start engine.

4.

Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-III. Check that engine speed var-
ies according to the valve opening.

Does engine speed vary according to the valve opening?

YES

>> GO TO 9.

NO

>> GO TO 8.

8.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE

Refer to 

EC-283, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 9.

NO

>> Replace EVAP canister purge volume control solenoid valve.

9.

CHECK RUBBER TUBE FOR CLOGGING

1.

Disconnect rubber tube connected to EVAP canister vent control valve.

2.

Check the rubber tube for clogging.

Is the inspection result normal?

YES

>> GO TO 10.

NO

>> Clean the rubber tube using an air blower.

10.

CHECK EVAP CANISTER VENT CONTROL VALVE

Refer to 

EC-290, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 11.

NO

>> Replace EVAP canister vent control valve.

11.

CHECK IF EVAP CANISTER SATURATED WITH WATER

1.

Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor
attached.

Water should not exist.

P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE

EC-283

< COMPONENT DIAGNOSIS >

[VQ35HR]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

2.

Check if water will drain from EVAP canister (1).

Does water drain from the EVAP canister?

YES

>> GO TO 12.

NO

>> GO TO 14.

12.

CHECK EVAP CANISTER

Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 2.1 kg (4.6 lb).

Is the inspection result normal?

YES

>> GO TO 14.

NO

>> GO TO 13.

13.

DETECT MALFUNCTIONING PART

Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehicle frame for clogging or poor connection

>> Repair hose or replace EVAP canister.

14.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-39, "Intermittent Incident"

.

>> INSPECTION END

Component Inspection

INFOID:0000000000956662

1.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE

 With CONSULT-III

1.

Turn ignition switch OFF.

2.

Reconnect all harness connectors disconnected.

3.

Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.

4.

Turn ignition switch ON.

5.

Select “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-III.

6.

Touch “Qd” and “Qu” on CONSULT-III screen to adjust “PURG
VOL CONT/V” opening and check air passage continuity of
EVAP canister purge volume control solenoid valve under the
following conditions.

 Without CONSULT-III

1.

Turn ignition switch OFF.

2.

Disconnect EVAP canister purge volume control solenoid valve harness connector.

3.

Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.

4.

Check air passage continuity of EVAP canister purge volume control solenoid valve under the following
conditions.

2

: EVAP canister vent control valve

PBIB2731E

Condition

(PURG VOL CONT/V value)

Air passage continuity 

between (A) and (B)

100%

Existed

0%

Not existed

JMBIA0068ZZ

EC-284

< COMPONENT DIAGNOSIS >

[VQ35HR]

P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace EVAP canister purge volume control solenoid valve

Condition

Air passage continuity 

between (A) and (B)

12V direct current supply between 
terminals 1 and 2

Existed

No supply

Not existed

P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID 

VALVE

EC-285

< COMPONENT DIAGNOSIS >

[VQ35HR]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE

Description

INFOID:0000000000956663

The EVAP canister purge volume control solenoid valve uses a ON/
OFF duty to control the flow rate of fuel vapor from the EVAP canis-
ter. The EVAP canister purge volume control solenoid valve is
moved by ON/OFF pulses from the ECM. The longer the ON pulse,
the greater the amount of fuel vapor that will flow through the valve.

DTC Logic

INFOID:0000000000956664

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

CONDITIONING

If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11V at idle.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

1.

Start engine and let it idle for at least 13 seconds.

2.

Check 1st trip DTC.

Is 1st trip DTC detected?

YES

>> Go to 

EC-285, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000000956665

1.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect EVAP canister purge volume control solenoid valve harness connector.

3.

Turn ignition switch ON.

4.

Check the voltage between EVAP canister purge volume control solenoid valve harness connector and
ground.

JMBIA0069ZZ

DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

P0444

EVAP canister purge volume 
control solenoid valve circuit 
open

An excessively low voltage signal is sent 
to ECM through the valve

• Harness or connectors

(The solenoid valve circuit is open or 
shorted.)

• EVAP canister purge volume control so-

lenoid valve

P0445

EVAP canister purge volume 
control solenoid valve circuit 
shorted

An excessively high voltage signal is sent 
to ECM through the valve

• Harness or connectors

(The solenoid valve circuit is shorted.)

• EVAP canister purge volume control so-

lenoid valve

 

 

 

 

 

 

 

Content   ..  532  533  534  535   ..