EC-190 < COMPONENT DIAGNOSIS > [VQ35HR] P0130, P0150 A/F SENSOR 1 4. Check the continuity between A/F sensor 1 harness connector or ECM harness connector and ground. 5. Also check harness for short to power. Is the inspection result normal? YES >> GO TO 5. NO >> Repair open circuit or short to ground or short to power in harness or connectors. 5. CHECK INTERMITTENT INCIDENT Perform GI-39, "Intermittent Incident" . Is the inspection result normal? YES >> GO TO 6. NO >> Repair or replace. 6. REPLACE AIR FUEL RATIO (A/F) SENSOR 1 Replace malfunctioning air fuel ratio (A/F) sensor 1. CAUTION: • Discard any A/F sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one. • Before installing new A/F sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant. >> INSPECTION END DTC A/F sensor 1 ECM Continuity Bank Connector Terminal Connector Terminal P0130 1 F3 1 F102 57 Existed 2 61 P0150 2 F20 1 65 2 66 DTC A/F sensor 1 ECM Ground Continuity Bank Connector Terminal Connector Terminal P0130 1 F3 1 F102 57 Ground Not existed 2 61 P0150 2 F20 1 65 2 66 |