Infiniti G35 (V35) Sedan. Manual - part 1371

 

  Index      Infiniti     Infiniti G35 (V35) Sedan - service repair manual 2007 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  1369  1370  1371  1372   ..

 

 

Infiniti G35 (V35) Sedan. Manual - part 1371

 

 

TM-176

< COMPONENT DIAGNOSIS >

[5AT: RE5R05A]

SHIFT LOCK SYSTEM

Check stop lamp switch. Refer to 

TM-177, "Component Inspection (Stop lamp switch)"

.

Is the inspection result normal?

YES-1 >> Without ICC: Repair or replace harness between stop lamp switch and shift lock relay.
YES-2 >> With ICC: GO TO 6.
NO

>> Replace stop lamp switch. Refer to 

BR-19, "Exploded View"

.

6.

CHECK DTC WITH ICC

 With CONSULT-III

Check the DTC of “ICC”. Refer to 

CCS-24, "CONSULT-III Function (ICC)"

.

Is any malfunction detected?

YES

>> Check the DTC detected item. Refer to 

CCS-24, "CONSULT-III Function (ICC)"

.

NO

>> Repair open circuit or short to power in harness or connectors.

7.

CHECK GROUND CIRCUT

1.

Check continuity between shift lock relay harness connector and ground.

2.

If OK, check harness for short to power.

Is the inspection result normal?

YES

>> GO TO 8.

NO

>> Repair open circuit or short to power in harness or connectors.

8.

CHECK SHIFT LOCK RELAY

Check shift lock relay. Refer to 

TM-177, "Component Inspection (Shift lock relay)"

.

Is the inspection result normal?

YES

>> GO TO 9.

NO

>> Replace shift lock relay.

9.

CHECK POWER SOURCE

1.

Turn ignition switch ON.

2.

Check voltage between shift lock relay harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 10.

NO

>>

Check the following. If NG, repair or replace damaged parts.

• 10 A fuse [No. 3, located in the fuse block (J/B)]
• Harness for short or open between ignition switch and shift lock relay harness connector termi-

nal 5

10.

CHECK GROUND CIRCUIT

1.

Disconnect A/T device harness connector.

2.

Check continuity between A/T device harness connector and ground.

3.

If OK, check harness for short to power.

Is the inspection result normal?

Shift lock relay harness connector

Ground

Continuity

Connector

Terminal

E52

1

Existed

(+)

(

)

Voltage (Approx.)

Shift lock relay harness connector

Ground

Connector

Terminal

E52

5

Battery voltage

A/T device harness connector

Ground

Continuity

Connector

Terminal

M137

9

Existed

SHIFT LOCK SYSTEM

TM-177

< COMPONENT DIAGNOSIS >

[5AT: RE5R05A]

C

E

F

G

H

I

J

K

L

M

A

B

TM

N

O

P

YES

>> GO TO 11.

NO

>> Repair open circuit or short to power in harness or connectors.

11.

CHECK SHIFT LOCK SOLENOID

Check shift lock solenoid. Refer to 

TM-177, "Component Inspection (Shift lock solenoid)"

.

Is the inspection result normal?

YES

>>

Check the following. If NG, repair or replace damaged parts.

• Harness for short or open between shift lock relay harness connector terminal 3 and A/T device

harness connector terminal 8

• Harness for short or open between A/T device harness conductor terminal 8 and shift lock unit

harness connector terminal 3

• Harness for short or open between A/T device harness conductor terminal 9 and shift lock unit

harness connector terminal 4

NO

>> Replace shift lock unit. Refer to 

TM-232, "2WD : Exploded View"

 (2WD), 

TM-233, "AWD :

Exploded View"

 (AWD).

Component Inspection (Shift lock solenoid)

INFOID:0000000000957106

1.

CHECK SHIFT LOCK SOLENOID

1.

Remove shift lock unit. Refer to 

TM-232, "2WD : Exploded View"

 (2WD), 

TM-233, "AWD : Exploded View"

(AWD).

2.

Apply voltage to terminals 3 and 4 of shift lock unit connector, and then check that shift lock solenoid is
activated.

CAUTION:

Connect the fuse between the terminals when applying the voltage.

Can the lock plate be moved up and down?

YES

>> INSPECTION END

NO

>> Replace shift lock unit. Refer to 

TM-232, "2WD : Exploded View"

 (2WD), 

TM-233, "AWD :

Exploded View"

 (AWD). 

Component Inspection (Shift lock relay)

INFOID:0000000000957107

1.

CHECK SHIFT LOCK RELAY

1.

Disconnect shift lock relay.

2.

Check continuity between shift lock relay terminal 3 and 5.

CAUTION:

Connect the fuse between the terminals when applying the voltage.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace shift lock relay.

Component Inspection (Stop lamp switch)

INFOID:0000000000957108

(+) (fuse)

(

)

Condition

Status

Shift lock unit connector

Connector

Terminal

Connector

Terminal

M222

3

M222

4

Apply 12 V direct 
current between ter-
minals 3 and 4. 

Shift lock solenoid 
operates

Shift lock relay connector 

Condition

Continuity

Connector

Terminal

Connector

Terminal

E52

3

E52

5

Apply 12 V direct 
current between ter-
minals 1 and 2. 

Existed

OFF

Not existed

TM-178

< COMPONENT DIAGNOSIS >

[5AT: RE5R05A]

SHIFT LOCK SYSTEM

1.

CHECK STOP LAMP SWITCH

1.

Disconnect stop lamp switch harness connector.

2.

Check continuity between stop lamp switch connector terminal 1 and 2.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace stop lamp switch. Refer to 

BR-19, "Exploded View"

.

Stop lamp switch connector

Condition

Continuity

Connector

Terminal

Connector

Terminal

E110

1

E110

2

Brake pedal de-
pressed

Existed

Brake pedal not de-
pressed

Not existed

SELECTOR LEVER POSITION INDICATOR

TM-179

< COMPONENT DIAGNOSIS >

[5AT: RE5R05A]

C

E

F

G

H

I

J

K

L

M

A

B

TM

N

O

P

SELECTOR LEVER POSITION INDICATOR

Description

INFOID:0000000000957109

Displays selector lever position.

Wiring Diagram

INFOID:0000000000957110

Refer to 

TM-182, "Wiring Diagram — A/T CONTROL SYSTEM —"

.

Component Inspection

INFOID:0000000000957111

1.

CHECK SELECTOR LEVER POSITION INDICATOR

Check that selector lever position indicator lamps turn on.

CAUTION:

Connect the fuse between the terminals when applying the voltage.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace the malfunctioning part. Refer to 

TM-232, "2WD : Exploded View"

 (2WD), 

TM-233, "AWD

: Exploded View"

 (AWD).

(+) (fuse)

(

)

Condition

Status

Selector lever position indicator

Connector

Terminal

Connector

Terminal

M221

5

M221

7

Apply 12 V direct 
current between ter-
minals 5 and 7. 

“P” position indica-
tor lamp illuminates

4

7

Apply 12 V direct 
current between ter-
minals 4 and 7. 

“R” position indica-
tor lamp illuminates

2

7

Apply 12 V direct 
current between ter-
minals 2 and 7. 

“N” position indica-
tor lamp illuminates

3

7

Apply 12 V direct 
current between ter-
minals 3 and 7. 

“D” position indica-
tor lamp illuminates

6

9

Apply 12 V direct 
current between ter-
minals 6 and 9. 

“M” mode indicator 
lamp illuminates

10

11

Apply 12 V direct 
current between ter-
minals 10 and 11. 

Night lamp illumi-
nates

 

 

 

 

 

 

 

Content   ..  1369  1370  1371  1372   ..