Content .. 1362 1363 1364 1365 ..
TM-148 < COMPONENT DIAGNOSIS > [5AT: RE5R05A] P1710 A/T FLUID TEMPERATURE SENSOR ATF TEMP SE 2>>GO TO 4. 2. CHECK A/T FLUID TEMPERATURE SENSOR 1 Check A/T fluid temperature sensor 1. Refer to TM-148, "Component Inspection (A/T fluid temperature sensor Is the inspection result normal? YES >> GO TO 3. NO >> Replace the control valve with TCM. Refer to 3. CHECK SUB-HARNESS 1. Disconnect park/neutral position switch connector and TCM connector. 2. Check continuity between park/neutral position switch connector and TCM connector. 3. If OK, check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 6. NO >> Replace open circuit or short to ground and short to power in harness or connectors. 4. CHECK A/T FLUID TEMPERATURE SENSOR 2 Check A/T fluid temperature sensor 2. Refer to TM-149, "Component Inspection (A/T fluid temperature sensor Is the inspection result normal? YES >> GO TO 5. NO >> Replace the A/T fluid temperature sensor 2. Refer to . 5. CHECK TERMINAL CORD ASSEMBLY 1. Disconnect A/T fluid temperature sensor 2 connector and TCM connector. 2. Check continuity between A/T fluid temperature sensor 2 connector terminals and TCM connector termi- 3. If OK, check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 6. NO >> Replace open circuit or short to ground and short to power in harness or connectors. 6. CHECK TCM POWER SUPPLY AND GROUND CIRCUIT Check TCM power supply and ground circuit. Refer to Is the inspection result normal? YES >> Replace the control valve with TCM. Refer to NO >> Repair or replace damaged parts. Component Inspection (A/T fluid temperature sensor 1) INFOID:0000000000957062 1. CHECK A/T FLUID TEMPERATURE SENSOR 2 1. Remove control valve with TCM. Refer to . 2. Check resistance between park/neutral position switch connector terminals. Park/neutral position switch connector TCM connector Continuity Connector Terminal Connector Terminal F154 6 F152 19 Existed 7 18 Existed A/T fluid temperature sensor 2 connector TCM connector Continuity Connector Terminal Connector Terminal F156 1 F151 3 Existed 2 5 Existed |