POWER SUPPLY AND GROUND CIRCUIT

SEC-107

< COMPONENT DIAGNOSIS >

[INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

SEC

N

O

P

POWER SUPPLY AND GROUND CIRCUIT

BCM

BCM : Diagnosis Procedure

INFOID:0000000000961457

1.

CHECK FUSE AND FUSIBLE LINK

Check that the following fuse and fusible link are not blown.

Is the fuse fusing?

YES

>> Replace the blown fuse or fusible link after repairing the affected circuit if a fuse or fusible link is

blown.

NO

>> GO TO 2.

2.

CHECK POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect BCM connectors.

3.

Check voltage between BCM harness connector and ground.

Is the measurement value normal?

YES

>> GO TO 3.

NO

>> Repair harness or connector.

3.

CHECK GROUND CIRCUIT

Check continuity between BCM harness connector and ground.

Does continuity exist?

YES

>> INSPECTION END

NO

>> Repair harness or connector.

BCM : Special Repair Requirement

INFOID:0000000000961458

1.

REQUIRED WORK WHEN REPLACING BCM

Initialize IVIS by CONSULT-III. For the details of initialization refer to CONSULT-III operation manual NATS-
IVIS/NVIS.

>> Work end.

IPDM E/R (INTELLIGENT POWER DISTRIBUTION MODULE ENGINE ROOM)

IPDM E/R (INTELLIGENT POWER DISTRIBUTION MODULE ENGINE ROOM) : Di-
agnosis Procedure

INFOID:0000000000961459

Terminal No.

Signal name

Fuse and fusible link No.

1

Battery power supply

K

11

10

Terminals

Voltage

(Approx.)

(+)

(

)

BCM

Ground

Connector

Terminal

M118

1

Battery voltage

M119

11

BCM

Ground

Continuity

Connector

Terminal

M119

13

Existed

SEC-108

< COMPONENT DIAGNOSIS >

[INTELLIGENT KEY SYSTEM]

POWER SUPPLY AND GROUND CIRCUIT

1.

CHECK FUSES AND FUSIBLE LINK

Check that the following IPDM E/R fuses or fusible links are not blown.

Is the fuse fusing?

YES

>> Replace the blown fuse or fusible link after repairing the affected circuit if a fuse or fusible link is

blown.

NO

>> GO TO 2.

2.

CHECK POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect IPDM E/R connector.

3.

Check voltage between IPDM E/R harness connector and ground.

Is the measurement value normal?

YES

>> GO TO 3.

NO

>> Repair harness or connector.

3.

CHECK GROUND CIRCUIT

Check continuity between IPDM E/R harness connectors and ground.

Does continuity exist?

YES

>> INSPECTION END

NO

>> Repair harness or connector.

Terminal No.

Signal name

Fuses and fusible link No.

1

Battery power supply

C

50

51

Terminals

Voltage

(Approx.)

(+)

(

)

IPDM E/R

Connector

Terminal

Ground

E4

1

Battery voltage

2

IPDM E/R

Ground

Continuity

Connector

Terminal

E5

12

Existed

E6

41

KEY SLOT

SEC-109

< COMPONENT DIAGNOSIS >

[INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

SEC

N

O

P

KEY SLOT

Diagnosis Procedure

INFOID:0000000000961460

1.

CHECK KEY SLOT POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect key slot connector.

3.

Check voltage between slot connector and ground.

Is the inspection result nornal?

YES

>> GO TO 2.

NO

>> Repair or replace key slot power supply circuit.

2.

CHECK KEY SLOT GROUND CIRCUIT

Check continuity between key slot connector and ground.

Is the inspection result nornal?

YES

>> GO TO 3.

NO

>> Repair or replace key slot ground circuit.

3.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-39, "Intermittent Incident"

.

>> INSPECTION END .

Key slot

Ground

Voltage (V)

(Approx.)

Connector

Terminal

M22

1

Ground

Battery voltage

5

Key slot

Ground

Continuity

Connector

Terminal

M22

7

Ground

Existed

SEC-110

< COMPONENT DIAGNOSIS >

[INTELLIGENT KEY SYSTEM]

KEY SLOT ILLUMINATION

KEY SLOT ILLUMINATION

Description

INFOID:0000000000961461

Blinks when Intelligent Key insertion is required.

Component Function Check

INFOID:0000000000961462

1.

CHECK FUNCTION

 With CONSULT-III

Check key slot illumination (“KEY SLOT ILLUMI”) Active Test mode.

Is the inspection result normal?

YES

>> Key slot function is OK.

NO

>> Refer to 

SEC-110, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000000961463

1.

CHECK KEY SLOT ILLUMINATION OUTPUT SIGNAL 

Check voltage between key slot connector and ground.

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> GO TO 2.

2.

CHECK KEY SLOT POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect key slot connector.

3.

Check voltage between slot connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace key slot power supply circuit.

3.

CHECK KEY SLOT GROUND CIRCUIT

Check continuity between key slot connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace key slot ground circuit.

Terminals

Condition

Key slot

illumination

Voltage (V)         

 (Approx.)

(+)

(–)

Key slot 

connector

Terminal

M22

6

Ground

Intelligent Key inserted

OFF

Battery voltage

Intelligent Key removed

ON

0

Terminals

Voltage (V)

(Approx.)

(+)

(–)

Key slot connector

Terminal

M22

1

Ground

Battery voltage

5

Key slot connector

Terminal

Ground

Continuity

M22

7

Existed

 

 

 

 

 

 

 