Content .. 1174 1175 1176 1177 ..
B2603 SHIFT POSITION STATUS SEC-59 < COMPONENT DIAGNOSIS > [INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B SEC N O P 4. Check continuity between A/T assembly harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair harness or connector. 3. CHECK A/T DEVICE POWER SUPPLY 1. Turn ignition switch OFF. 2. Disconnect A/T device (detention switch) harness connector. 3. Check voltage between A/T device (detention switch) harness connector and ground. Is the inspection result normal? YES >> GO TO 5. NO >> GO TO 4. 4. CHECK A/T DEVICE POWER SUPPLY CIRCUIT 1. Disconnect BCM harness connector M122. 2. Check continuity between A/T device (detention switch) harness connector and BCM harness connector. 3. Check continuity between A/T device (detention switch) harness connector and ground. Is the inspection result normal? YES >> Replace BCM. Refer to BCS-79, "Removal and Installation" NO >> Repair harness or connector. 5. CHECK A/T DEVICE CIRCUIT 1. Disconnect BCM harness connector M122. 2. Check continuity between A/T device (detention switch) harness connector and BCM harness connector. 3. Check continuity between A/T device (detention switch) harness connector and ground. Is the inspection result normal? YES >> GO TO 6. NO >> Repair harness or connector. A/T assembly Ground Continuity Connector Terminal F51 9 Ground Not existed A/T device (detention switch) Ground Voltage [V] Connector Terminal M137 10 Ground Battery voltage A/T device (detention switch) BCM Continuity Connector Terminal Connector Terminal M137 10 M122 96 Existed A/T device (detention switch) Ground Continuity Connector Terminal M137 10 Ground Not existed A/T device (detention switch) BCM Continuity Connector Terminal Connector Terminal M137 11 M122 99 Existed A/T device (detention switch) Ground Continuity Connector Terminal M137 11 Ground Not existed |