Infiniti G35 (V35) Sedan. Manual - part 1097

 

  Index      Infiniti     Infiniti G35 (V35) Sedan - service repair manual 2007 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  1095  1096  1097  1098   ..

 

 

Infiniti G35 (V35) Sedan. Manual - part 1097

 

 

PWC-220

< ECU DIAGNOSIS >

[FRONT WINDOW ANTI-PINCH]

FRONT POWER WINDOW SWITCH

JCKWA0055GB

FRONT POWER WINDOW SWITCH

PWC-221

< ECU DIAGNOSIS >

[FRONT WINDOW ANTI-PINCH]

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

Fail Safe

INFOID:0000000000961724

FAIL-SAFE CONTROL

Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control when error beyond regulation value is detected between
the fully closed position and the actual position of the glass.

JCKWA0056GB

PWC-222

< ECU DIAGNOSIS >

[FRONT WINDOW ANTI-PINCH]

FRONT POWER WINDOW SWITCH

It changes to condition before initialization and the following functions do not operate when switched to fail-
safe control.
• Auto-up operation
• Anti-pinch function
• Retained power function

Perform initial operation to recover when switched to fail-safe mode. However, it switches back to fail-safe
control when malfunction is found in power window switch or in motor.

Error

Error condition

Pulse sensor malfunction

When only one side of pulse signal is being detected for more than the specified value.

Both pulse sensors mal-
function

When both pulse signals have not been detected for more than the specified value during glass open/
close operation.

Pulse direction malfunction

When the pulse signal that is detected during glass open/close operation detects the opposite condition 
of power window motor operating direction.

Glass recognition position 
malfunction 1

When it detects the error between glass fully closed position in power window switch memory and actual 
fully closed position during glass open/close operation is more than the specified value.

Glass recognition position 
malfunction 2

When it detects pulse count more than the value of glass full stroke during glass open/close operation.

Malfunction of not yet up-
dated closed position of 
glass

When glass open/close operation is continuously performed without fully closing more than the specified 
value (approximately 10 strokes).

NONE OF THE POWER WINDOWS CAN BE OPERATED USING ANY SWITCH

PWC-223

< SYMPTOM DIAGNOSIS >

[FRONT WINDOW ANTI-PINCH]

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

SYMPTOM DIAGNOSIS

NONE OF THE POWER WINDOWS CAN BE OPERATED USING ANY
SWITCH

Diagnosis Procedure

INFOID:0000000000961725

1.

CHECK BCM POWER SUPPLY AND GROUND CIRCUIT

Check BCM power supply and ground circuit.
Refer to 

BCS-38, "Diagnosis Procedure"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace the malfunctioning parts.

2.

CHECK POWER WINDOW MAIN SWITCH POWER SUPPLY AND GROUND CIRCUIT

Check power window switch main power supply and ground circuit.
Refer to 

PWC-136, "POWER WINDOW MAIN SWITCH : Component Function Check"

.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace the malfunctioning parts.

3.

CHECK POWER WINDOW MAIN SWITCH SERIAL CIRCUIT

Check power window main switch serial circuit.
Refer to 

PWC-136, "POWER WINDOW MAIN SWITCH : Component Function Check"

.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace the malfunctioning parts.

4.

CHECK POWER WINDOW MAIN SWITCH

Check power window main switch.
Refer to 

PWC-136, "POWER WINDOW MAIN SWITCH : Component Function Check"

.

Is the inspection result normal?

YES

>> Inspection end.

NO

>> Check intermittent incident. Refer to 

GI-39, "Intermittent Incident"

.

 

 

 

 

 

 

 

Content   ..  1095  1096  1097  1098   ..