Infiniti FX35 / FX45. Manual - part 404

 

  Index      Infiniti     Infiniti FX35 / FX45 (S50) - service repair manual 2008 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  402  403  404  405   ..

 

 

Infiniti FX35 / FX45. Manual - part 404

 

 

DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

EC-377

< SERVICE INFORMATION >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

Wiring Diagram

INFOID:0000000001326209

Specification data are reference values and are measured between each terminal and ground.

CAUTION:

Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.

TBWM1392E

EC-378

< SERVICE INFORMATION >

[VQ35DE]

DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

Diagnosis Procedure

INFOID:0000000001326210

1.

CHECK GROUND CONNECTIONS

1.

Turn ignition switch OFF.

2.

Loosen and retighten ground screw on the body. Refer to 

EC-144, "Ground Inspection"

.

OK or NG

OK

>> GO TO 2.

NG

>> Repair or replace ground connections.

2.

CHECK CONNECTOR

1.

Disconnect EVAP control system pressure sensor harness connector.

2.

Check sensor harness connector for water.

OK or NG

OK

>> GO TO 3.

NG

>> Repair or replace harness connector.

3.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT

1.

Turn ignition switch ON.

TER-

MI-

NAL 

NO.

WIRE 

COLOR

ITEM

CONDITION

DATA (DC Voltage)

32

OR

EVAP control system pres-
sure sensor

[Ignition switch: ON]

Approximately 1.8 - 4.8V

48

LG

Sensor power supply
(EVAP control system pres-
sure sensor)

[Ignition switch: ON]

Approximately 5V

67

B/W

Sensor ground

[Engine is running]
• Warm-up condition
• Idle speed

Approximately 0V

PBIB2625E

Water should not exist.

PBIB1611E

DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

EC-379

< SERVICE INFORMATION >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

2.

Check voltage between EVAP control system pressure sensor
terminal 3 and ground with CONSULT-III or tester.

OK or NG

OK

>> GO TO 5.

NG

>> GO TO 4.

4.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B201, M81
• Harness connectors M82, F102
• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit or short to ground or short to power in harness or connectors.

5.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT

1.

Turn ignition switch OFF.

2.

Disconnect ECM harness connector.

3.

Check harness continuity between EVAP control system pressure sensor terminal 1 and ECM terminal
67.
Refer to Wiring Diagram.

4.

Also check harness for short to ground and short to power.

OK or NG

OK

>> GO TO 7.

NG

>> GO TO 6.

6.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B201, M81
• Harness connectors M82, F102
• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit or short to ground or short to power in harness or connectors.

7.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND

SHORT

1.

Check harness continuity between ECM terminal 32 and EVAP control system pressure sensor terminal
2.
Refer to Wiring Diagram.

2.

Also check harness for short to ground and short to power.

OK or NG

OK

>> GO TO 9.

NG

>> GO TO 8.

8.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B201, M81
• Harness connectors M82, F102

Voltage: Approximately 5V

PBIB0138E

Continuity should exist.

Continuity should exist.

EC-380

< SERVICE INFORMATION >

[VQ35DE]

DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit or short to ground or short to power in harness or connectors.

9.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

Refer to 

EC-380, "Component Inspection"

.

OK or NG

OK

>> GO TO 10.

NG

>> Replace EVAP control system pressure sensor.

10.

CHECK INTERMITTENT INCIDENT

Refer to 

EC-139

.

>> INSPECTION END

Component Inspection

INFOID:0000000001326211

EVAP CONTROL SYSTEM PRESSURE SENSOR

1.

Remove EVAP control system pressure sensor with its harness connector connected from EVAP canister.
Always replace O-ring with a new one.

2.

Install a vacuum pump to EVAP control system pressure sensor.

3.

Turn ignition switch ON and check output voltage between ECM
terminal 32 and ground under the following conditions.

CAUTION:

• Always calibrate the vacuum pump gauge when using it.
• Do not apply below -93.3 kPa (-700 mmHg, -27.56 inHg) or

pressure over 101.3 kPa (760 mmHg, 29.92 inHg).

4.

If NG, replace EVAP control system pressure sensor.

Applied vacuum kPa

(mmHg, inHg)

Voltage V

Not applied

1.8 - 4.8

-26.7 (-200, -7.87)

2.1 to 2.5V lower than above value

PBIB1173E

 

 

 

 

 

 

 

Content   ..  402  403  404  405   ..