P1220 FUEL PUMP CONTROL MODULE (FPCM) EC-1001 < DTC/CIRCUIT DIAGNOSIS > [VK50VE] C D E F G H I J K L M A EC N P O 7. CHECK FUEL PUMP CONTROL CIRCUIT FOR OPEN AND SHORT 1. Disconnect “fuel level sensor unit and fuel pump (main)” harness connector. 2. Check the continuity between FPCM harness connector and “fuel level sensor unit and fuel pump (main)” 3. Also check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 8. NO >> Repair open circuit, short to ground or short to power in harness or connectors. 8. CHECK FPCM EC-1001, "Component Inspection" . Is the inspection result normal? YES >> GO TO 9. NO >> Replace FPCM. 9. CHECK INTERMITTENT INCIDENT GI-36, "Intermittent Incident" . >> INSPECTION END Component Inspection INFOID:0000000005237481 1. CHECK FUEL PUMP CONTROL MODULE (FPCM) 1. Check the voltage between FPCM terminals under the following conditions. Is the inspection result normal? YES >> INSPECTION END NO >> Replace FPCM. FPCM Fuel level sensor unit and fuel pump (main) Continuity Connector Terminal Connector Terminal B31 6 B22 3 Existed 7 1 FPCM Condition Voltage Connector + − Terminal Terminal B31 7 6 For 1 second after turning ignition Approx. 8.5 V More than 1 second after turning Approx. 0 V Idle speed Approx. 8.5 V |