AV SIDE CAMERA RH IMAGE SIGNAL CIRCUIT AV-541 < DTC/CIRCUIT DIAGNOSIS > [NAVIGATION (TWIN MONITOR)] C D E F G H I J K L M B A O P SIDE CAMERA RH IMAGE SIGNAL CIRCUIT Description INFOID:0000000005525412 • Around view monitor control unit supplies to the front camera, rear camera and side camera. And then it superimpose the images from each camera and outputs then to the display unit. • Superimpose the guiding lines, predicted course line and sonar indicator to the camera image that outputs to the front display unit. • Around view monitor control unit performs the reception/transmission of communication signal with each camera. Diagnosis Procedure INFOID:0000000005474908 1. CHECK CONTINUITY SIDE CAMERA RH POWER SUPPLY AND GROUND CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect control unit connector and door mirror (passenger side) connector. 3. Check continuity between around view monitor control unit harness connector and door mirror (passenger 4. Check continuity between around view monitor control unit harness connector and ground. Is inspection result normal? YES >> GO TO 2. NO >> Repair harness or connector. 2. CHECK VOLTAGE SIDE CAMERA RH POWER SUPPLY 1. Connect around view monitor control unit connector and door mirror (passenger side) connector. 2. Turn ignition switch ON. 3. Check voltage between around view monitor control unit harness connector and ground. Is inspection result normal? YES >> GO TO 3. NO >> Replace around view monitor control unit. Refer to . 3. CHECK CONTINUITY SIDE CAMERA RH IMAGE SIGNAL CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect around view monitor control unit connector and door mirror (passenger side) connector. 3. Check continuity between around view monitor control unit harness connector and door mirror (passenger Around view monitor control unit Door mirror (passenger side) Continuity Connector Terminals Connector Terminals B46 32 D33 18 Existed 34 6 Around view monitor control unit Ground Continuity Connector Terminal B46 34 Not existed (+) ( − ) Condition Voltage (Approx.) Around view monitor control unit Connector Terminal B46 34 Ground “CAMERA” switch is ON or 6.0 V |