AV SYSTEM AV-173 < SYSTEM DESCRIPTION > [NAVIGATION (SINGLE MONITOR)] C D E F G H I J K L M B A O P • Sonar control unit has the diagnosis function. It can detect the corner sensor malfunction or sensor harness open circuit. It transmits the diagnosis results to around view monitor control unit and always displays the Obstacle Detection Distance • Sonar control unit changes the outputs of the sonar indicator and warning buzzer in 3 stages according to the obstacle detection distance from the corner sensor. • The sonar control unit can change the setting of obstacle detection distance in 4 stages. Obstacle detection image Detection distance Sonar Indicator Display • Around view monitor control unit that receives the detection signal and detection distance signal from sonar control unit displays the sonar indicator on display. • Around view monitor control unit changes the color or blinking cycle of the indicator according to the detec- tion distance. JSNIA1430ZZ A. Approx. 50 cm (19.6 in) B. Approx. 15 cm (5.9 in) Warning item Sensitivity level 1 (Faster warning) Sensitivity level 2 (Default value) Sensitivity level 3 (Slower warning) Sensitivity level 4 (Slowest warning) First stage 70 – 80 cm (27.5 – 31.4 in) 60 – 70 cm (23.6 – 27.5 in) 50 – 60 cm (19.6 – 23.6 in) 40 – 50 cm (15.7 – 19.6 in) Second stage 50 – 70 cm (19.6 – 27.5 in) 40 – 60 cm (15.7 – 23.6 in) 30 – 50 cm (11.8 – 19.6 in) 30 – 40 cm (11.8 – 15.7 in) Third stage Less than 50 cm (19.6 in) Less than 40 cm (15.7 in) Less than 30 cm (11.8 in) Less than 30 cm (11.8 in) |