EXL-248 < COMPONENT DIAGNOSIS > [HALOGEN TYPE] PARKING LAMP CIRCUIT PARKING LAMP CIRCUIT Component Function Check INFOID:0000000003756981 1. CHECK PARKING LAMP OPERATION IPDM E/R AUTO ACTIVE TEST 1. Activate IPDM E/R auto active test. Refer to EXL-37, "Diagnosis Description" 2. Check that the parking lamp is turned ON. CONSULT-III ACTIVE TEST 1. Select "EXTERNAL LAMPS" of IPDM E/R active test item. 2. With operating the test items, check that the parking lamp is turned ON. Is the parking lamp turned ON? YES >> Parking lamp circuit is normal. NO >> Refer to EXL-248, "Diagnosis Procedure" . Diagnosis Procedure INFOID:0000000003756982 1. CHECK PARKING LAMP FUSE 1. Turn the ignition switch OFF. 2. Check that the following fuses are not fusing. Is the fuse fusing? YES >> GO TO 2. NO >> GO TO 3. 2. CHECK PARKING LAMP SHORT CIRCUIT 1. Disconnect IPDM E/R connector and the front combination lamp connector. 2. Check continuity between the IPDM E/R harness connector and the ground. Does continuity exist? YES >> Repair the harnesses or connectors. And then replace the fuse. NO >> Replace the fuse. (Replace IPDM E/R if fusing is found again.) 3. CHECK PARKING LAMP BULB Check the applicable lamp bulb. YES >> GO TO 4. NO >> Replace the bulb. 4. CHECK PARKING LAMP OUTPUT VOLTAGE CONSULT-III ACTIVE TEST 1. Disconnect the front combination lamp connector. 2. Turn the ignition switch ON. 3. Select "EXTERNAL LAMPS" of IPDM E/R active test item. TAIL : Parking lamp ON Off : Parking lamp OFF Unit Location Fuse No. Capacity Parking lamp IPDM E/R #52 10 A IPDM E/R Ground Continuity Connector Terminal RH E9 91 Not existed LH 92 |