3. Unscrew the fastening screw -2- for the line to the compressor and pull the line out of the compressor line. 4. Pull the line out of the line holder and take it out. Installing compressor-condenser line Installing compressor-condenser line Note When loosening or tightening the M8 refrigerant lines on the condenser, always counter with a 21-mm Pulling line out of holder 1. Clip line into the line holder at the top and engage it in the rubber mounting. Note Before re-installing the component, check the O-rings of the refrigerant lines for damage and replaced them if 2. Insert compressor-condenser line into the line to the compressor and fasten with the fastening screw -2- . → Tightening torque: 14 (10.5 ftlb.) Nm 3. Close and engage holder for rubber mounting. Diagnostic system: reading out fault memory and activating systems Installing compressor-condenser line 3593 |