Content .. 1199 1200 1201 1202 ..
87 IN Technical data, air-conditioning system - as of Technical data for air-conditioning system Air conditioning Refrigerant Filling capacity of Climatronic 900g R134a 195 +/- 15 cm 3 ND 8 General pressures bar High-pressure cut-off 32 Low-pressure cut-off at ambient temperature > 5 °C 1.4 (1.0) High-pressure cut-off at ambient temperature < 5 °C 0,5 Pressure relief valve purge pressure 40 Refrigerant distribution in circuit approx. cm 3 Compressor 50 Condenser (2 x 20 cm 3 ) 40 Evaporator 30 Fluids with containers 30 Circulating oil quantity in the refrigerant circuit 60 Tightening torques for air-conditioning system Note When installing the refrigerant lines, the screw connections must always be wet with refrigerant oil. Installation Location: 4961 |